JOHNSON MATTHEY ELECTRONICS, INC -- CADMIUM -- 6810-00-975-0693
===================== Product Identification =====================
Product ID:CADMIUM
MSDS Date:01/14/1994
FSC:6810
NIIN:00-975-0693
=== Responsible Party ===
Company Name:JOHNSON MATTHEY ELECTRONICS, INC
Address:EAST 15128 EUCLID AVENUE
City:SPOKANE
State:WA
ZIP:99216-1895
Country:US
Info Phone Num:509-924-2200
Emergency Phone Num:509-924-2200
CAGE:JOMCC
=== Contractor Identification ===
Company Name:JOHNSON MATTHEY CATALOG CHEMICALS
Address:152 ANDOVER STREET
City:DANVERS
State:MA
ZIP:01923
Country:US
Phone:508-777-1970
CAGE:JOMCC
Company Name:JOHNSON MATTHEY ELECTRONICS, INC
Address:EAST 15128 EUCLID AVENUE
Box:City:SPOKANE
State:WA
ZIP:99216-1895
Country:US
Phone:509-924-2200
CAGE:0R9V7
============= Composition/Information on Ingredients =============
Ingred Name:CADMIUM (SARA 313) (CERCLA)
CAS:7440-43-9
RTECS #:EU9800000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG/M3 DUST; Z-2
ACGIH TLV:0.01 MG/M3 DUST;9596
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 ORAL RAT: 1000 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE POISONING FOLLOWING INGESTION
CAUSES GI DISTURBANCES, SALIVATION, SHOCK, LIVER & KIDNEY DAMAGE.
MAY CAUSE DEATH. SKIN CONTACT MAY BE IRRITATING. EYE CONTACT MAY BE
IRRITATING. INHALATION CAUSES PULMONARY DISTURBANCES, WEAKNESS,
LEG PAIN, FEVER AND LUNG CONGESTION. MAY CAUSE PERMANENT CHANGE TO
LUNGS.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:GI DISTURBANCES, SALIVATION, SHOCK,
LIVER/KIDNEY DAMAGE, DEATH, SKIN IRRITATION, EYE IRRITATION,
PULMONARY DISTURBANCES, WEAKNESS, LEG PAIN, FEVER, LUNG CONGESTION,
LUNG DAMAGE, ANOSMIA, DYSPNEA, DISC OLORATION OF TEETH. MAY
INCREASE RISK OF PROSTATE, RESPIRATORY, GENITOURINARY CANCERS.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH LUNG, LIVER,
KIDNEY AND BLOOD DISORDERS MAY BE AT INCREASED RISK.
======================= First Aid Measures =======================
First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
MEDICAL ATTENTION. INGESTION: NO SPECIFIC INFORMATION AVAILABLE,
ONE SHOULD OBTAIN MEDICAL ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:DO NOT USE WATER OR CARBON DIOXIDE. USE DRY
CHEMICAL EXTINGUISHING AGENTS, DRY SAND OR DRY GROUND DOLOMITE.
Fire Fighting Procedures:USE NORMAL PROCEDURES WHICH INCLUDE WEARING
NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING APPARATUS, FLAME AND
CHEMICAL RESISTANT CLOTHING, HATS, BOOTS & GLOVES.
Unusual Fire/Explosion Hazard:FLAMMABLE SOLID IN DUST OR POWDER FORM.
FIRE AND EXPLOSION HAZARD IN THE FORM OF DUST WHEN EXPOSED TO HEAT
OR FLAME OR BY CHEMICAL REACTION.
================== Accidental Release Measures ==================
Spill Release Procedures:WEARING FULL PROTECTIVE EQUIPMENT, COVER SPILL
WITH DRY SAND OR VERMICULITE. MIX WELL AND CAREFULLY TRANSFER TO A
CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED. STORE
IN A COOL, DRY WELL-VENTILATED AREA. WASH THOROUGHLY AFTER USE.
Other Precautions:THIS PRODUCT CONTAINS A CHEMICAL KNOWN TO THE STATE
OF CALIFORNIA TO CAUSE CANCER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:HIGH EFFICIENCY PARTICLE RESPIRATOR.
Ventilation:GLOVE BAG OR BOX WITH A DRY INERT ATMOSPHERE
Protective Gloves:RUBBER
Eye Protection:ANSI APPROVED SAFETY GOGGLES W/SHIELD
Other Protective Equipment:CHEMICAL RESISTANT CLOTHING AS NECESSARY TO
PREVENT SKIN CONTACT. AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
THIS PRODUCT CONTAINS CADMIUM WHICH IS SUBJECT TO THE REPORTING
REQUIRMENTS OF SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY
RIGHT-TO-KNOWN ACT OF 1986 AND 40CFR 372.
================== Physical/Chemical Properties ==================
HCC:F8
Boiling Pt:B.P. Text:1409F,765C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:1
Vapor Density:NOT GIVEN
Spec Gravity:8.65
Evaporation Rate & Reference:O (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:SILVER-WHITE, BLUE-TINGED, LUSTROUS METAL,
ODORLESS.
Percent Volatiles by Volume:0 %
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS, ACIDS, S, SE, TE, K, ZN, AMMONIUM NITRATE, HYDRAZOIC
ACID, AIR, HEAT.
Stability Condition to Avoid:HEAT, FLAME.
Hazardous Decomposition Products:CADMIUM OXIDES, HYDROGEN GAS, NITROGEN
OXIDES.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONSULT STATE, LOCAL OR FEDERAL EPA REGULATIONS
FOR PROPER DISPOSAL. RCRA HAZARDOUS WASTE CODE: D006.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.